8. FAULT CODE 050 OR 052: TOO MANY NO START ATTEMPTS OR NO START
SAFETY TIME EXCEEDED (CONT).
8.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Fuel level OK (checked at
Visual inspection.
on Page 2-766.63
operational level).
Arctic heater intake port checks
REASON FOR QUESTION
OK at unit level.
Arctic heater exhaust port and
Fault code 050 must be cleared
Does arctic heater operate af-
exhaust tube checks OK at unit
to clear lockout mode before test-
level.
ter fault code 050 is cleared
ing can continue.
Arctic heater fuel lines check OK
or arctic heater control unit is
at unit level.
replaced?
Arctic heater fuel metering pump
OK.
Arctic heater fuel system primed.
Arctic heater flame sensor OK.
Arctic heater glow pin OK.
Fault not cor-
POSSIBLE PROBLEMS
NO
rected. Notify su-
Arctic heater in lockout mode
pervisor.
(fault code 050 active).
YES
Go to Step 7 of
this Fault.