Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical circuits, a
S
direct short may result. Damage to equipment, injury or death to personnel may occur.
Fuel is very flammable and can explode easily. To avoid serious injury or death, keep fuel away from open fire
S
and keep fire extinguisher within easy reach when working with fuel. Do not work on fuel system when engine is
hot. Fuel can be ignited by hot engine.
NOTE
Audible clicking and low fuel flow from the fuel metering pump may indicate that the arctic heater fuel
S
system isn't primed. The arctic heater should self- prime itself within ten start attempts (five start
-
cycles).
If arctic heater does not operate, arctic heater may be in lockout mode due to too many start
S
attempts (code 050). Arctic heater lockout mode (code 050) is activated if arctic heater fails to start
after 20 successive start attempts (10 successive start cycles).
VISUAL INSPECTION
(1) Connect fuel line on arctic heater and
tighten screw (TM 9-2320-364-20).
(2) Check fuel in fuel tank. Add fuel if required
to ensure fuel is supplied to arctic heater.
(3) Turn arctic heater switch ON
(TM 9-2320-364-10).
(4) Observe arctic heater for proper
operation. Note if audible clicking is heard
from arctic heater fuel metering pump.
(5) When arctic heater shuts down after two
start attempts, turn arctic heater switch
OFF.
(6) Repeat Steps (3) through (5) four times or
until arctic heater operates normally.
(a) If arctic heater does not operate,
when arctic heater switch is turned
ON (lockout mode activated), go to
Step 5 of this Fault.
(b) If arctic heater fuel metering pump
fails to prime itself within ten start
attempts (five start cycles), replace
arctic heater fuel metering pump
(TM 9-2320-364-20).
(c) If arctic heater fuel metering pump
primes itself within ten start attempts
(five start cycles), fault has been
corrected.
821