Page Title: FAULT CODE 050 OR 052: TOO MANY NO START ATTEMPTS OR NO START SAFETY TIME EXCEEDED. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical circuits, a
S
direct short may result. Damage to equipment, injury or death to personnel may occur.
Fuel is very flammable and can explode easily. To avoid serious injury or death, keep fuel away from open fire
S
and keep fire extinguisher within easy reach when working with fuel. Do not work on fuel system when engine is
hot. Fuel can be ignited by hot engine.
NOTE
If arctic heater does not operate, arctic heater may be in lockout mode due to too many start
S
attempts (code 050). Arctic heater lockout mode (code 050) is activated if arctic heater fails to start
after 20 successive start attempts (10 successive start cycles).
Audible clicking and low fuel flow from the fuel metering pump may indicate that the arctic heater fuel
S
system isn't primed.
Fuel should flow from fuel line into container 63 seconds after arctic heater starts. Fuel will shut off
S
automatically after 105 seconds. Fuel will begin flow again after 50 to 60 second preheat, and will
turn off after 75 seconds (This indicates two start attempts). The arctic heater will shut down after
the second start attempt (one start cycle).
Total fuel quantity should be between 0.62 to 0.65 ounces (18.64 and 19.36 ml) in Steps (5) and (6).
S
VISUAL INSPECTION
(1) If installed, remove fault code retrieval
device (FCRD).
(2) Loosen clamp screw and disconnect
arctic heater fuel line from arctic heater
(TM 9-2320-364-20).
(3) Place arctic heater fuel line into graduated
1 quart (950 ml) measuring container.
(4) Turn arctic heater switch ON
(TM 9-2320-364-20).
(5) Observe fuel flowing into measuring
container.
(6) Turn arctic heater switch OFF when
fuel stops flowing after second start
attempt.
(7) Inspect measuring container for 0.62 to
0.65 ounces (18.64 to 19.36 ml).
(a) If arctic heater does not operate,
(lockout mode activated), perform
Step (8) below and go to Step 2 of
this Fault.
(b) If no or low fuel delivery and audible
clicking is heard from fuel metering
pump, go to Step 4 of this Fault.
(c) If fuel metering pump delivers less
than 0.62 ounces (18.64 ml) of fuel,
perform Step (8) below and replace
arctic heater fuel metering pump
(TM 9-2320-364-20).
(d) If fuel metering pump delivers
between 0.62 and 0.65 ounces (18.64
and 19.36 ml) of fuel, perform Step (8)
below and go to Step 6 of this Fault.
(8) Connect arctic heater fuel line to arctic
heater and tighten clamp screw.
2-819 -53