TM 9-2320-364-34-1
2-17.1. ARCTIC HEATER (MODEL B) TROUBLESHOOTING (CONT).
6. FAULT CODE 037, 042 OR 059: WATER PUMP IS NOT WORKING WATER
PUMP SHORT CIRCUIT OR WATER TEMPERATURE RISES TOO QUICKLY.
INITIAL SETUP
References
Tools and Special Tools
TM 9-2320-364-10
Tool Kit, General Mechanic's: Automotive
TM 9-2320-364-20
(Item 241, Appendix F)
Equipment Condition
STE/ICE-R (optional) (Item 15, Appendix F)
Engine OFF, (TM 9-2320-364-10)
Multimeter (Item 140, Appendix F)
Parking brake applied, (TM 9-2320-364-10)
Fault Code Retrieval Device (FCRD)
Wheels chocked, (TM 9-2320-364-10)
(Item 60.1, Appendix F)
NOTE
The following steps should only be used if troubleshooting was started at First Chart
for Diagnosis of Arctic Heater Troubleshooting procedures (Para 2-17.1 Fault 1) (all
conditions) and you were referred here.
START
1.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
Coolant level checked at unit
Continuity test.
on Page 2-766.43
level.
STE/ICE-R #91.
Arctic heater coolant hose and
REASON FOR QUESTION
hose clamps checked at unit
level.
If resistance reading is be-
Is resistance measured across
Arctic heater coolant shutoff
tween 650 and 1000 ohms at
valves checked at unit level.
arctic heater temperature sen-
room temperature, arctic heater
sor between 650 and 1000
coolant pump may be faulty. If
POSSIBLE PROBLEMS
ohms, at room temperature?
not, arctic heater temperature
Arctic heater temperature
sensor is faulty.
sensor faulty.
Arctic heater coolant pump
faulty.
Replace arctic
heater tempera-
ture sensor
NO
(Para 18-2.2).
Verify repair, go
to Step 2 of this
Fault.
YES
Replace arctic
heater coolant
pump (Para
18-2.2). Verify
repair, go to
Step 2 of this
fault.
2-428
80
|