TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical circuits, a direct short
may result. Damage to equipment, injury or death to personnel may occur.
VOLTAGE TEST
(1) Turn arctic heater switch OFF
(TM 9-2320-364-10).
(2) Remove cable tie from arctic heater
internal harness.
(3) Connect arctic heater internal harness
connector to arctic heater control unit
internal connector (Para 18-2.2).
(4) Connect (back probe) positive (+) lead
to violet wire at arctic heater internal
harness connector, terminal 13.
(5) Connect (back probe) negitive (-) lead
to green wire at arctic heater internal
harness connector, terminal 5.
(6) Turn arctic heater switch ON.
(a) If 2.2 to 2.8 vdc are not present,
replace arctic heater blower
(Para 18-2.2).
(b) If 2.2 to 2.8 vdc are present,
replace arctic heater control unit
(Para 18-2.2).
2-802-39