TM 9-2320-364-34-1
3. FAULT CODE 012, 013, 014 OR 015: OVERHEATING, EXCESSIVE TEMPERATURE
AT FLAME SENSOR, POSSIBLE OVERHEATING DETECTED OR TOO MANY
OVERHEATS (CONT).
4.
TEST OPTIONS
KNOWN INFO
WARNING
Read WARNING
Visual inspection.
Arctic heater coolant level
on Page 2-766.19
checks OK unit level.
Arctic heater coolant hoses and
REASON FOR QUESTION
valves check OK unit level.
If system is in lockout due to too
Arctic heater temperature sensor
many overheats, arctic heater
OK.
Does arctic heater operate?
will not operate and arctic heater
Arctic heater overheat sensor OK.
indicator light will flash flash code
Arctic heater flame sensor OK.
015.
Arctic heater coolant pump OK.
POSSIBLE PROBLEMS
Arctic heater in lockout mode
If arctic heater indicator light
(fault code 15 active).
flashes flash code shown and
the fault code retrieval device
(FCRD) is not available, re-
place arctic heater control unit
(Para 18-2.2). Verify repair,
go to Step 6 of this Fault.
NO
If arctic heater fault code re-
trieval device (FCRD) dis-
plays a fault code 15 or the
arctic heater indicator light
flashes flash code shown and
the fault code retrieval device
(FCRD) is available, go to
Step 5 of this Fault.
YES
Go to Step 6 of this
Fault.