TM 9-2320-364-34-1
3. FAULT CODE 012, 013, 014 OR 015: OVERHEATING, EXCESSIVE TEMPERATURE
AT FLAME SENSOR, POSSIBLE OVERHEATING DETECTED OR TOO MANY
OVERHEATS (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Arctic heater coolant level
Continuity test.
on Page 2-766.15
checks OK unit level.
Arctic heater coolant hoses and
REASON FOR QUESTION
valves check OK unit level.
Arctic heater temperature sensor
Is resistance across arctic
OK.
If resistance reading is not be-
heater overheat sensor be-
tween 10K and 150K ohms at
POSSIBLE PROBLEMS
room temperature, arctic heater
tween 10K and 150K ohms, at
overheat sensor is faulty.
room temperature?
Arctic heater overheat sensor
faulty.
Arctic heater flame sensor faulty.
Arctic heater coolant pump faulty.
Arctic heater in lockout mode
Replace arctic heat-
(fault code 15 active).
er overheat sensor
(Para 18-2.2). Verify
NO
repair, go to Step 4
of this Fault.
YES
2-140
-78
|