TM 9-2320-364-34-1
2-17.1. ARCTIC HEATER (MODEL B) TROUBLESHOOTING (CONT).
2. FAULT CODE 001, 002, 010, OR 011: ADVANCED WARNING - OVERVOLTAGE
SHUTDOWN, ADVANCED WARNING - UNDERVOLTAGE SHUTDOWN,
OVERVOLTAGE SHUTDOWN OR UNDERVOLTAGE SHUTDOWN.
INITIAL SETUP
References
TM 9-2320-364-10
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, General Mechanic's: Automotive
(Item 241, Appendix F)
Equipment Condition
STE/ICE-R (optional) (Item 15, Appendix F)
Engine OFF, (TM 9-2320-364-10)
Multimeter (Item 140, Appendix F)
Parking brake applied, (TM 9-2320-364-10)
Fault Code Retrieval Device (FCRD)
Wheels chocked, (TM 9-2320-364-10)
(Item 60.1, Appendix F)
NOTE
The following steps should only be used if troubleshooting was started at First Chart
for Diagnosis of Arctic Heater Troubleshooting procedures (Para 2-17.1 Fault 1) (all
conditions) and you were referred here.
START
1.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Visual inspection.
Battery checks OK at unit
on Page 2-766.11
level.
REASON FOR QUESTION
Arctic heater power circuit
check OK at unit level.
If arctic heater operates nor-
Vehicle 24 volt charging
mally after replacing arctic
system check OK at unit level.
Does arctic heater operate
heater control unit, fault has
normally after replacing arctic
been corrected.
POSSIBLE PROBLEMS
heater control unit?
Arctic heater control unit faulty.
If arctic heater indicator
flashes or fault code retrieval
device (FCRD) displays fault
code 001, 002, 010 or 011,
fault not corrected. Notify
supervisor.
NO
If arctic heater indicator
flashes or fault code retrieval
device (FCRD) displays fault
code other than 001, 002,
010 or 011, troubleshoot fault
YES
code displayed (TM
9-2320-364-20).
Fault corrected.
-776