TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical circuits, a direct short
may result. Damage to equipment, injury or death to personnel may occur.
NOTE
Refer to arctic heater (Model B) troubleshooting (TM 9-2320-364-20) for fault code retrieval device
S
(FCRD) operation.
Perform Steps (2) and (3) only if fault code retrieval device (FCRD) is available.
S
VISUAL INSPECTION
(1) Ensure vehicle is returned to normal
operating condition.
(2) Install fault code retrieval device
(FCRD) on arctic heater unit harness
diagnostic connector.
(3) Press the D button on fault code
retrieval device (FCRD) to turn arctic
heater ON.
(4) Turn arctic heater ON
(TM 9-2320-364-10).
(5) Observe arctic heater for proper
operation.
(6) Turn arctic heater switch to OFF
(TM 9-2320-364-10) or press the
D button on the fault code retrieval
device (FCRD), if installed.
(a) If arctic heater operates normally
fault has been corrected.
Remove fault code retrieval
device (FCRD) and install arctic
heater cover (TM 9-2320-364-20).
(b) If arctic heater does not operate
normally, replace arctic heater
control unit (Para 18-2.2) and
go to Step 3 of this Fault.
2-772-7
3
|