TM 9-2320-364-34-1
2-17.1. ARCTIC HEATER (MODEL B) TROUBLESHOOTING (CONT).
1. FAULT CHART FOR DIAGNOSTIC OF ARCTIC HEATER
TROUBLESHOOTING (MODEL B).
INITIAL SETUP
References
TM 9-2320-364-10
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, General Mechanic's: Automotive
(Item 241, Appendix F)
Equipment Condition
STE/ICE-R (optional) (Item 15, Appendix F)
Engine OFF, (TM 9-2320-364-10)
Multimeter (Item 140, Appendix F)
Parking brake applied, (TM 9-2320-364-10)
Fault Code Retrieval Device (FCRD)
Wheels chocked, (TM 9-2320-364-10)
(Item 60.1, Appendix F)
NOTE
All unit level troubleshooting must be completed before performing this procedure.
START
1.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
on Page 2-766.5
Arctic heater indicator light
Visual inspection.
wires tested OK at unit level.
REASON FOR QUESTION
POSSIBLE PROBLEMS
Does arctic heater indicator
Flash code dictates trouble-
light or fault code retrieval de-
shooting logic.
Diagnostic codes present.
vice (FCRD) display a fault
Arctic heater control unit faulty.
code?
Go to Step 2 of
NO
this Fault.
YES
Troubleshoot fault
code displayed as
indicated on Page
2-766.5
2-470
-7
|