1. SELF-RECOVERY WINCH (SRW) DOES NOT OPERATE (CONT).
3.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting tasks
Visual inspection.
completed.
Crane and LHS operate.
REASON FOR QUESTION
Does multifunction manifold
If shuttle valve is faulty, pump
POSSIBLE PROBLEMS
shuttle valve check ball have
control will not recieve load
sense pressure.
Shuttle valve faulty.
freedom of movement?
Winch control manifold faulty.
Counterbalance valve faulty.
SRW motor faulty.
Replace shuttle valve
(Para 17-18).
NO
Verify repair, Go to
Step 7 of this Fault.
YES
Replace winch control
manifold
(Para 16-37).
Verify repair, go to
Step 7 of this Fault.
2-734