TM 9-2320-364-34-1
13. BOOM DOES NOT TELESCOPE OR TELESCOPES SLOWLY (CONT).
2.
TEST OPTIONS
KNOWN INFO
Operation test.
Unit Troubleshooting
Does boom telescope when
tasks completed.
BOOM control lever is held in
REASON FOR QUESTION
Crane swings.
the UP position?
If load sense check valve in four
POSSIBLE PROBLEMS
valve bank is faulty, pump
control will not receive load
Four valve bank faulty.
sense pressure. If BOOM
Boom chain or cable faulty.
control lever is held in the UP
Telescope cylinder
position while attempting to
faulty.
telescope, pump control will
sense load sense pressure from
BOOM circuit.
Go to Step 3 of this
NO
Fault.
YES
Repair four valve
bank (Para 16-26).
Verify repair, go to
Step 7 of this Fault.
2-578
|