TM 9-2320-364-34-1
11. BOOM DOES NOT TELESCOPE IN OR TELESCOPES IN SLOWLY (CONT).
Cable must be held when disconnected and
allowed to retract slowly by hand. Failure
to do so may result in equipment damage.
OPERATION TEST (CONT).
(16) Operate telescope cylinders using
TELE control lever.
(a) If one cylinder does not operate
or operates slowly, perform
Steps (17) through (25) below
and replace telescope cylinder
(Para 16-10).
(b) If both cylinders operate equally
or both do not operate, fault not
corrected. Perform Steps (17)
through (25) and notify
supervisor.
(17) Set crane POWER switch to
OFF position (TM 9-2320-364-10).
(18) Set hydraulics selector switch to
OFF position.
(19) Turn OFF ENGINE switch.
Continued on next page.