TM 9-2320-364-34-1
8. CRANE DOES NOT SWING OR SWINGS SLOWLY (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting
Flowmeter test.
tasks completed.
Are a
Outriggers operate.
REASON FOR QUESTION
minimum
Telescope operates.
of 4 gpm (15 lpm) measured
If SWING valve or orifice is faulty
from SWING valve with valve
pressure and flow to swing motor
POSSIBLE PROBLEMS
isolated from swing motor
will be restricted.
and SWING control lever held
Four valve bank faulty.
in both CW and CWW
Swing motor valve
position?
faulty.
Swing motor faulty.
Swing brake faulty.
Go to Step 7 of this
NO
Fault.
YES
2-516