TM 9-2320-364-34-1
OPERATION TEST
(1) Operate crane mast using MAST
control lever (TM 9-2320-364-10).
(a) If mast operates slowly in
both directions, perform Steps (2)
through (4) below and go to
Step 5 of this Fault.
(b) If mast operates slowly in one
direction and normally in the
other, cylinder is faulty. Replace
erection cylinder (Para 16-5).
(2) Set crane POWER switch to
OFF position.
(3) Set hydraulic selector switch to OFF
position.
(4) Turn OFF ENGINE switch.
2-489
|