TM 9-2320-364-34-1
OPERATION TEST
(1) Cut safety wire from MHC
SYSTEM HYDRAULIC PRESSURE
MANUAL OVERRIDE button.
(2) Push in MHC SYSTEM HYDRAULIC
PRESSURE MANUAL OVERRIDE
push button.
(3) Attempt to operate outriggers using
O/R JACK control levers.
(a) If outriggers do not operate,
perform Steps (4) through (6)
below and go Step 4 of this Fault.
(b) If outriggers operate,
perform Steps (4) through (6)
below, and repair solenoid valve
assembly (Para 16-24).
(4) Set crane POWER switch to
OFF position.
(5) Set hydraulic selector switch to
OFF position.
(6) Turn OFF ENGINE switch.
2-433
|