10. LOSS OF MIDDLE FRAME LOAD HOLDING (CONT).
4.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting tasks
Flowmeter test.
on Page 2-397
completed.
LHS operates.
REASON FOR QUESTION
Main cylinder manifold relief
Are 0 gpm measured at RH
If fluid flow is getting past RH
valve OK.
main manifold, port VA with
main cylinder piston seals,
LH main cylinder OK.
middle frame will not hold load.
LHS in transit position while
POSSIBLE PROBLEMS
holding joystick in LOAD
position?
RH main cylinder faulty.
Load control valve faulty.
Replace RH main
cylinder (Para 17-15).
NO
Verify repair, go to
Step 5 of this Fault.
YES
Replace load control
valve (Para 17-6).
Verify repair, go to
Step 5 of this Fault.