TM 9-2320-364-34-1
6. MIDDLE FRAME DOES NOT LOAD (CONT).
3.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting tasks
Pressure test.
on Page 2-329
completed.
Middle frame unloads.
REASON FOR QUESTION
Middle frame down directional
Are 0 psi measured at RH
control valve OK.
If relief valve is faulty, pressure
main cylinder manifold, port T
Load control valve OK.
will be relieved out port T before
operating cylinder.
when attempting to load?
POSSIBLE PROBLEMS
Main cylinder manifold
relief valve faulty.
Load control valve faulty.
LH main cylinder faulty.
Repair RH main
RH main cylinder faulty.
cylinder manifold
NO
(Para 17-16).
Verify repair, go to
Step 8 of this Fault.
YES
2-328
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |