Click here to make tpub.com your Home Page

Page Title: FAN DOES NOT OPERATE AT HIGH SPEED. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
VERIFY REPAIR
(1) Check hydraulic oil level and add oil
as necessary (TM 9-2320-364-20).
(2) Start engine (TM 9-2320-364-10).
(3) Inspect fan operation.
(a) If fan does not operate at high
speed, fault not corrected.
Perform Steps (4) through (7)
below and notify supervisor.
(b) If fan operates at high speed,
fault has been corrected.
(4) Turn OFF ENGINE switch.
(5) Install LHS control box cover,
four lockwashers and screws.
(6) Install left side noise panel
eight washers, lockwashers
and screws.
(7) Connect connector MC59 to EPAC
controller.