VERIFY REPAIR
(1) Check hydraulic oil level and add oil
as necessary (TM 9-2320-364-20).
(2) Start engine (TM 9-2320-364-10).
(3) Listen and observe fan.
(a) If fan speed does not lower, fault
not corrected. Perform Steps (4)
through (6) below and notify
supervisor.
(b) If fan speed lowers, fault has
been corrected.
(4) Turn OFF ENGINE switch.
(5) Install LHS control box cover
and four lockwashers and screws.
(6) Install left side noise panel, eight
lockwashers and screws.
2-223