VERIFY REPAIR
(1) Install an ATEC cartridge in DDR
(TM 9-2320-364-20).
(2) Connect DDR cable to DDL
connector MC13.
(3) Start engine (TM 9-2320-364-10).
(4) Clear codes on DDR reader.
(5) Check DDR for an active code 15.
(a) If a code 15 is not displayed, fault
has been corrected. Perform
Steps (6) through (8) below.
(b) If a code 15 is displayed, fault not
corrected. Perform Steps (6)
through (8) below and notify
supervisor.
(6) Turn OFF ENGINE switch.
(7) Disconnect DDR cable from DDL
connector MC13.
(8) Install left rear fender skirt
(TM 9-2320-364-20).