1.
PERFORM REMOVAL STEPS 1 THRU 4.
2.
PLACE TEMPERATURE SLIDE LEVER (1) IN FULLY CLOSED POSITION. CHECK TO SEE IF SLIDE LEVER (2)
ON WATER CONTROL VALVE (3) IS IN FULLY HORIZONTAL POSITION.
3.
IF NOT, ROTATE ADJUSTING TURNBUCKLE (4) UNTIL SLIDE LEVER (2) IS IN FULLY HORIZONTAL
POSITION.
4.
PLACE TEMPERATURE SLIDE LEVER (1) IN FULLY OPEN POSITION. CHECK TO SEE IF SLIDE LEVER (2)
ON WATER CONTROL VALVE (3) IS IN FULLY VERTICAL POSITION.
5.
IF NOT, ROTATE ADJUSTING TURNBUCKLE (4) UNTIL SLIDE LEVER (2) IS IN FULLY VERTICAL POSITION.
6.
REPEAT STEPS 2 THRU 5 UNTIL BOTH ADJUSTMENTS HAVE BEEN FULLY ACHIEVED.
7.
PERFORM INSTALLATION STEPS 14 THRU 17.
NOTE
Follow-on Maintenance:
Connect batteries (page 2-29).
Fill with coolant (Unit PMCS, TM 9-2320-363-20-1).