TM 9-2320-363-20-2
TRANSMISSION TUNNEL ACCESS COVER REPLACEMENT (CONT)
NOTE
To ease installation, note number of threads when removing pivot pins.
3.
LOOSEN NUT (7) AND REMOVE PIVOT PIN (8) FROM TRANSMISSION CONTROL CABLE (9).
4.
FOR M916A2. REPEAT STEP 3 FOR TRANSFER CASE CONTROL CABLE (10).
5.
FOR M917A1 AND M917A1 W/MCS, REPEAT STEP 3 FOR TRANSFER CASE CONTROL CABLE (10) AND
HYDRAULIC CONTROL CABLE (11).
6.
REMOVE 12 SCREWS (12), AND 12 LOCK WASHERS (13) FROM ACCESS COVER (14). DISCARD LOCK
WASHERS.
7.
REMOVE GROMMETS (15) FROM ACCESS COVER (14).
8.
LIFT ACCESS COVER (14) OVER CONTROL CABLES.
INSTALLATION
1.
FOR M916A2, INSERT CONTROL CABLE ENDS THROUGH HOLES PROVIDED IN ACCESS COVER (1) WITH
TRANSMISSION CONTROL CABLE (2) ON LEFT, AND TRANSFER CASE CONTROL CABLE (3) ON RIGHT.
2.
FOR M917A1 AND M917A1 W/MCS, INSERT CONTROL CABLE ENDS THROUGH HOLES PROVIDED IN
ACCESS COVER (1) WITH TRANSMISSION CONTROL CABLE (2) ON LEFT, TRANSFER CASE CONTROL
CABLE (3) IN CENTER, AND HYDRAULIC CABLE (4) ON RIGHT.
4-756.2 Change 3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |