TM 9-2320-363-20-2
CTIS QUICK RELEASE VALVE MAINTENANCE (CONT)
CLEANING/INSPECTION
Clean and inspect all parts in accordance with
Chapter 2.
ASSEMBLY
1.
INSTALL NEW PREFORMED
PACKING
(1)
ONTO SNORKEL ADAPTER (2).
NOTE
Orient snorkel exhaust port same as
when removed.
2.
BY HAND, PRESS SNORKEL ADAPTER (2)
ONTO QUICK RELEASE VALVE (3) UNTIL LEGS
ON SNORKEL ADAPTER ENGAGE SEAT ON
QUICK RELEASE VALVE.
INSTALLATION
1.
WITH AIR INLET PORT UP, SECURE QUICK RELEASE VALVE (3) WITH TWO BOLTS (4), FOUR
FLATWASHERS (5), AND TWO NUTS (6).
2.
INSTALL TWO ADAPTERS (7) AND CONNECT TWO AIR HOSES (8) TO TW O AIR OUTLET PORTS.
3.
INSTALL ADAPTER (9), TEE (10), AND CONNECT TWO AIR HOSES (11) TO AIR INLET PORT.
4-604.28 Change 3
|