T M 9-2320-363-20-2
CLEANING/lNSPECTION
Clean and inspect all parts in accordance with Chapter 2.
I N S T A L L A T IO
N
WARNING
M a k e sure all air lines and fittings are clear of debris. Make sure excess
p i p e sealant compound does not enter air lines or fittings. Failure to do so
c o u l d result in equipment failure and/or injury to personnel.
S e a l a n t compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open
f i r e and use in well-ventilated area. If sealant compound gets on skin or
c l o t h i n g , wash immediately with soap and water.
1.
COAT THREADS WITH PIPE SEALANT COMPOUND AND INSTALL PIPE NIPPLE (12), TWO-WAY
CHECK VALVE (11), TWO CONNECTORS (10), TWO TEES (9), AND TWO ELBOWS (8) IN
QUICK-RELEASE VALVE (3).
INSTALL QUICK-RELEASE VALVE (3), TWO WASHERS (7), TWO SCREWS (6), TWO WASHERS
2.
(5), AND TWO NEW LOCK NUTS (4).
3.
CONNECT FOUR HOSES (1) AND TWO TUBES (2) TO QUICK-RELEASE VALVE (3).
4-551
|