Page Title: INSTALLATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-363-20-2
FRONT
SERVICE
BRAKE
RELAY
VALVE
REPLACEMENT
(CONT)
INSTALLATION
WARNING
Z Make sure all air lines and fittings are clear of debris. Make sure excess
p i p e sealant compound does not enter air lines or fittings. Failure to do so
c o u l d result in equipment failure and/or injury to personnel.
Z Sealant compounds can burn easily,
can give off harmful vapors, and are
harmful to skin and clothing. To avoid
injury or death, keep away from open
f i r e and use in well-ventilated area.
If sealant compound gets on skin or
c l o t h i n g , wash immediately with soap
and water.
1.
COAT PIPE THREADS OF FOUR ELBOWS (1) AND PLUG (2) WITH PIPE SEALANT COMPOUND.
2.
INSTALL FOUR ELBOWS (1) AND PLUG (2) IN BRAKE RELAY VALVE (3).
INSTALL BRAKE RELAY VALVE (3), TWO WASHERS (4), TWO SCREWS (5), TWO WASHERS (6),
3.
AND TWO NEW LOCK NUTS (7) ON CROSSMEMBER (8).
4-536