TM 9-2320-363-20-2
CLEANING/INSPECTION
Clean and inspect all parts in accordance with Chapter 2.
INSTALLATION
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe
sealant compound does not enter air lines or fittings. Failure to do so could
result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open
fire and use in well-ventilated area.  If sealant compound gets on skin or
clothing, wash immediately with soap and water.
NOTE
Procedure is the same for all vehicles except as noted.
Step 1 is for M915A2 only.
Step 2 is for all except M915A2 only.
1.
COAT THREADS WITH PIPE SEALANT COMPOUND AND INSTALL THREE PLUGS (1), TWO ELBOWS (2),
THREE CONNECTORS (3), AND CONNECTOR (4) IN CONSTANT AIR JUNCTION BLOCK (5).
2.
COAT THREADS WITH PIPE SEALANT COMPOUND AND INSTALL FOUR PLUGS (6), ELBOW (7), TW O
CONNECTORS (8), CONNECTOR (9), AND FITTING (10) IN CONSTANT AIR JUNCTION BLOCK (5).
Change 3 4-519