TM 9-2320-363-20-2
INSTALLATION
NOTE
Procedure is the same for all air tubes.
1.
INSTALL NUT (1), FERRULE (5), AND INSERT (4) ON AIR TUBE (3).
WARNING
Make sure all air lines and fittings are clear of debris. Make sure exce ss pipe sealant compound
does not enter air lines or fittings. Failure to do so could result in equipment failure and/or injury
to personnel.
Sealant compounds can bum easily, can give off harmful vapors, and are harmful to skin and
clothing To avoid injury or death, keep away from open fire and use in well-ventilated area. If
sealant compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Route air tube so that tube does not bend to radius smaller than allowed in Nylon Tube
Bend Radius Table. If bent smaller than allowed, tube may kink causing loss of air
pressure to component.
2.
COAT THREADS OF FITTING (2) WITH PIPE SEALANT COMPOUND AND INSTALL AIR TUBE (3) IN FITTING
(2).
3.
INSTALL NUT (1) ON FITTING (2).
Nylon Tube Bend Radius Table
Outside
Minimum Bend
Diameter
Radius
in.
(mm)
in.
(mm)
0.25
(6.40)
1.0
(25.0)
0.38
(9.50)
1.5
(38.0)
0.50
(13.00)
2.0
(51.0)
0.63
(17.00)
2.5
(64.0)
0.75
(19.00)
3.0
(76.0)
NOTE
Follow-on Maintenance:
Perform standard leak test (page 2-24).