TM 9-2320-363-20-2
INSTALLATION
NOTE
Procedure is the same for all air tubes.
1.
INSTALL NUT (l), FERRULE (5), AND INSERT (4) ON AIR TUBE (3).
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess
pipe sealant compound does not enter air lines or fittings. Failure to do so
c o u l d result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open
f i r e and use in well-ventilated area. If sealant compound gets on skin or
c l o t h i n g , wash immediately with soap and water.
CAUTION
R o u t e air tube so that tube does not bend to radius smaller than allowed in
N y l o n Tube Bend Radius Table. If bent smaller than allowed, tube may kink
c a u s i n g loss of air pressure to component.
2.
COAT THREADS OF FlTTING (2) WITH PIPE SEALANT COMPOUND AND INSTALL AIR TUBE (3)
IN FlTTING (2).
INSTALL NUT (1) ON FlTTING (2).
3.
Nylon Tube Bend Radius Table
Minimum Bend Radius
Outside Diameter
(mm)
in.
(mm)
in.
1.0
(25.0)
0.25
(6.40)
1.5
(38.0)
(9.50)
0.38
2.0
(51.0)
(13.00)
0.50
(17.00)
2.5
(64.0)
0.63
(76.0)
(19.00)
0.75
3.0
NOTE
Follow-on Maintenance:
P e r f o r m standard leak test (page 2-24).
4-505
|