TM
9-2320-363-20-2
INSTALLATION
NOTE
P e r f o r m steps 1 thru 4 only if fittings have been removed from air tank.
1.
INSTALL TWO MOUNTING BRACKETS (1), TWO SCREWS (2), AND TWO NEW LOCK NUTS (3), ON
.-
. .-
.
AIR SUPPLY TANK (4).
WARNING
M a k e sure all air lines and fittings are clear of debris. Make sure excess
p i p e sealant compound does not enter air lines or fittings. Failure to do so
c o u l d result in equipment failure and/or injury to personnel.
S e a l a n t compounds can burn easily,
can give off harmful vapors, and are
harmful to skin and clothing. To avoid
injury or death, keep away from open
f i r e and use in well-ventilated area,
If sealant compound gets on skin or
c l o t h i n g , wash immediately with soap
and water.
2.
COAT PIPE THREADS WITH PIPE SEALANT COMPOUND AND INSTALL DRAIN VALVE (5), CABLE
(6), AND NEW COTTER PIN (7).
3.
COAT PIPE THREADS OF NEW TEE (8), NEW CHECK VALVE (9), NEW BUSHING (10), TWO NEW
T E E S (11), NEW SAFETY VALVE (12), THREE NEW ELBOWS (13), AND THREE NEW
CONNECTORS (14) WITH PIPE SEALANT COMPOUND.
4.
INSTALL TEE (8), CHECK VALVE (9), BUSHING (10), TWO TEES (1 1), SAFETY VALVE (12), THREE
ELBOWS (13), AND THREE CONNECTORS (14) ON NEW AIR SUPPLY TANK (4).
INSTALL AIR SUPPLY TANK (4), CABLE (6), FIVE WASHERS (15), AND FOUR NEW LOCK NUTS (16).
5.
6.
CONNECT SIX TUBES (17) TO AIR SUPPLY TANK (4).
4-485
|