REMOVAL
NOTE
T a g all tubes prior to disconnecting to aid in connecting.
1.
DISCONNECT SIX TUBES (1) FROM AIR SUPPLY TANK (2).
2.
DISCONNECT TUBE (3) FROM PRIMARY 1 AIR TANK (4).
3.
REMOVE FOUR LOCK NUTS (5) AND FOUR WASHERS (6) AND SET PRIMARY I AIR TANK (4)
ASIDE. DISCARD LOCK NUTS.
4.
REMOVE COTTER PIN (7) AND DISCONNECT CABLE (8). DISCARD COTTER PIN.
REMOVE FOUR LOCK NUTS (9), FOUR WASHERS (10), FOUR SCREWS (11), FOUR WASHERS
5.
(12), AND AIR SUPPLY TANK (2). DISCARD LOCK NUTS.