WARNING
M a k e sure all air lines and fittings are clear of debris. Make sure excess
pipe sealant compound does not enter air lines or fittings. Failure to do so
could result in equipment failure and/or injury to personnel.
S e a l a n t compounds can burn easily, can give off harmful vapors, and a r e
harmful to skin and clothing. To avoid injury or death, keep away from open
f i r e and use in well-ventilated area. If sealant compound gets on skin or
c l o t h i n g , wash immediately with soap and water.
3.
COAT PIPE THREADS OF NEW PLUG (9), NEW CHECK VALVE (10) NEW DRAIN VALVE (11),
NEW PRESSURE PROTECT VALVE (12), NEW BUSHING (13), THREE NEW TEES (14), TWO NEW
CONNECTORS (15), AND FIVE NEW ELBOWS (16) WITH PIPE SEALANT COMPOUND.
4.
INSTALL PLUG (9), CHECK VALVE (10), DRAIN VALVE (11), PRESSURE PROTECT VALVE (12),
BUSHING (13), THREE TEES (14), TWO CONNECTORS (15), AND FIVE ELBOWS (16) ON NEW
AIR TANK (17).
5.
INSTALL AIR TANK (17), TWO SCREWS (18), AND TWO NEW LOCK NUTS (19).
CONNECT HOSE (20) AND SIX TUBES (21) TO AIR TANK (17).
6.
NOTE
Follow-on  Maintenance:
Install spare tire (TM 9-2320-363-10).
P e r f o r m standard leak test (page 2-24).