TM 9-2320-363-20-2
TRANSFER CASE SHIFT CONTROL CABLE REPLACEMENT AND
ADJUSTMENT (CONT)
ADJUSTMENT
NOTE
During step 1, do not release shift selector after shift selector seats in LOW
RANGE position detent.
Shift selector must be in NEUTRAL position.
1.
SLOWLY PUSH SHIFT SELECTOR (1) FORWARD UNTIL SHIFT SELECTOR (1) SEATS IN LOW RANGE
POSITION DETENT, THEN ATTEMPT TO PUSH LEVER FORWARD FROM THAT POSITION.
2.
IF SHIFT SELECTOR (1) WENT FARTHER THAN LOW RANGE POSITION DETENT, LOOSEN NUT (2) AND
RAISE STOP BLOCK (3) SLIGHTLY. REPEAT STEP 1.
3.
REPEAT STEPS 1 AND 2 UNTIL THERE IS NO MOVEMENT WHEN SHIFT SELECTOR IS MOVED FROM
NEUTRAL TO LOW RANGE.