TM 9-2320-363-20-2
SHIFT TOWER REPLACEMENT (CONT)
INSTALLATION
1.
IF INSTALLED, REMOVE FRONT AND REAR ACCESS PANELS FROM SHIFT TOWER. TO KEEP SHIFT
TOWER RIGID, REINSTALL TWO TOP AND TWO BOTTOM SCREWS ON FRONT AND REAR OF SHIFT
TOWER.
2.
WITH TRANSMISSION SELECTOR LEVER ON
LEFT, POSITION SHIFT TOWER (1) ON CAB
FLOOR AND INSTALL FOUR BOLTS (2).
NOTE
Perform steps 3 through 5 for M917A1 and M917A1 w/MCS.
3.
WITH HYDRAULIC CONTROL LEVER IN "DOWN" POSITION, INSTALL HYDRAULIC CONTROL CABLE PIVOT
PIN (3) IN BRACKET (4) AND SECURE WITH RETAINING PIN (5). REMOVE TAG FROM CABLE (6).
4.
INSTALL SPACER (7), CABLE (6), CLAMP (8), TWO SCREWS (9), TWO NEW LOCK WASHERS (10), AND TWO
NUTS (11) TO BRACKET (12).
5.
PLACE HYDRAULIC CONTROL LEVER IN "N" POSITION.
4-366.8 Change 3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |