TM 9-2320-363-20-2
4.
INSTALL GROMMET ON BRANCH OF WIRING HARNESS (4) LEADING TO CIRCUIT BREAKER PANEL (8)
INSIDE CAB. ROUTE HARNESS THROUGH FIREWALL TO CIRCUIT 98A ON CIRCUIT BREAKER PANEL.
5.
INSTALL GROMMET INTO FIREWALL AND SECURE HARNESS WITH TIE WRAPS.
6.
CONNECT WIRING HARNESS CONNECTOR TO CIRCUIT 98A ON CIRCUIT BREAKER PANEL (8).
7.
INSTALL FUSE, RELAY, AND CIRCUIT BREAKER HOLDER (PAGE 4-205.0).
8.
INSTALL ACCESS PANEL (9) AND LOCK THREE FASTENERS (10) BY TURNING CLOCKWISE.
NOTE
Follow-on Maintenance:
Connect batteries(page 2-29).
Operate heater/air conditioner (TM 9-2320-363-10).
Change 3 4-333.5
|