TM 9-2320-363-20-2
WATER PUMP REPLACEMENT (CONT)
INSTALLATION
WARNING
Snap ring may snap off and could injure personnel.
Use face shield when
removing snap ring.
1.
REMOVE SNAP RING (1) FROM WATER PUMP (2).
2.
REMOVE WATER PUMP COVER (3) AND SEAL (4) FROM WATER PUMP (2). DISCARD SEAL.
3.
LUBRICATE NEW SEAL (5) WITH THIN FILM OF CLEAN LUBRICATING OIL.
4.
INSTALL NEW SEAL (5) IN GROOVE OF WATE R PUMP (2).
5.
INSTALL WATER PUMP (2), TWO LONG BOLTS (6), AND SHORT BOLT (7) ON GEAR HOUSING (8),
MESHING WATER PUMP GEAR WITH CRANKSHAFT TIMING GEAR. TIGHTEN BOLTS TO 43-54 LB-FT (58-
73 N.m).