28-2. WINCH REPAIR (CONT)
NOTE
Right and left side cable damps are
installed the same way. Left side is
shown.
(18) Install cable clamp (17) on side support
(18) with two screws (19) and new
locknuts (20). Torque to 200 lb-ft (271
Nm).
(19) Install side support (18) on end supports
(8 and 13) with two screws (21), new
lockwashers (22), and nuts (23). Do not
tighten.
(20) Install six screws (24), new lockwashers
(25), and nuts (26) on side support (18).
(21) Tighten two nuts (23) and six nuts (26) to
200 lb-ft (271 Nm).
(22) Repeat steps (19) thru (21) for remaining
side support (27).
28-20
|