NOTE
Oil seal is installed properly when top
surface of seal is 1/16 in. (1.59 mm)
below housing.
(16) Install new oil seal (19) on output housing
(13).
WARNING
On direct contact, uncured silicone
sealant irritates eyes.
In case of
contact, flush eyes with water and
seek medical attention.  In case of
skin contact, wipe off and flush with
water.
(17) Coat splines of output shaft (20) with
silicone adhesive-sealant.
(18) Coat threads of output shaft (20) with
silicone adhesive-sealant.
NOTE
Large openings of yoke must align
with notches in input shaft to ease
staking of nut
(19) Install output yoke (21) and new nut (22)
on output shaft (20) using socket (22.1).
(20) Tighten nut (22) to 486-572 lb-ft (659-775
Nm).
(21) Stake edges of nut (22) in notches of shaft
(20).