TM 9-2320-360-34-2
20-3. TURBOCHARGER REPAIR (CONT)
(5) Install turbine wheel (7) in holding fixture (8).
(6) Remove locknut (9) from shaft (10) with aid of
assistant. Discard locknut.
(7) Tap shaft (10) with soft-faced hammer while
assistant holds center housing (6) up
approximately 1 in. (25.4 mm) above holding
fixture (8) to loosen impeller (11).
CAUTION
Do not pry off impeller.
Damage to
impeller may result.
(8) Remove impeller (11) from shaft (10).
(9) Remove center housing (6) from shaft (10).
WARNING
Wear eye protection and use care
when removing retaining rings.
Retaining rings are under spring
tension and can act as projectiles
when released causing severe eye
Injury.
(10) Remove retaining ring (12) from shaft (10).
Discard retaining ring.
(11) Remove turbine wheel shroud (13) from turbo
wheel shaft (10).
(12) Remove four screws (14) and backplate (3) from
center housing (6).
(13) Remove seal ring (15) from center housing (6).
Discard seal ring.
(14) Remove thrust spacer (16) from backplate (3).
(15) Remove two metal seal rings ( 7) from thrust
1
spacer (16). Discard seal rings.
20-18
|