TM 9-2320-360-34-1
NOTE
If multimeter does not indicate an
open circuit in either test, rotor coil is
grounded. Replace rotor.
(11)
Touch one test lead to bare metal surface
on shaft (8) and other test lead separately
to each slip ring (9).
NOTE
If resistance is not 10.0 ohms or less,
replace rotor.
(12)
Touch test leads to each slip ring (9).
NOTE
Minimum outside diameter (OD) of
slip rings is 1.057 in. (26.85 mm). If
measurement is less, replace rotor.
(13)
Measure outside diameter (OD) of slip
rings (9).
NOTE
Minimum outside diameter (OD) of
shaft is 0.669 in. (17 mm). If
measurement is less, replace rotor.
(14)
Measure diameter of shaft (8).
c.
Cleaning/lnspection
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in well-ventilated area. Avoid contact with skin, eyes, and
clothing, and don't breathe vapors. DO NOT use near open flame or excessive
heat. The flash point is 100-138° F (38-59° C). If you become dizzy while using
cleaning solvent, get fresh air immediately and medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
CAUTION
Do not soak stator or rotor in solvents. Damage to insulation may result.
(1)
Clean stator and rotor with dry cleaning solvent and clean cloth.
6-23
|