TM 9-2320-360-34-1
(3)
Remove nut (5) and solenoid (6) from
cartridge (7).
(4)
Remove cartridge (7) from counterbalance
valve (2).
(5)
Remove two preformed packings (8), four
split rings (9), and preformed packing (10)
from cartridge (7). Discard preformed
packings and split rings.
(6)
Remove plug (11) from counterbalance
valve (2).
(7)
Remove two backup rings (12) and two
preformed
packings
(13)
from
counterbalance valve (2). Discard backup
rings and preformed packings.
(8)
Remove adapter (14) from counterbalance
valve (2).
(9)
Remove preformed packing (15) from
adapter (14). Discard preformed packing.
c.
Cleaning/Inspection
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use solvent only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes, and don't breathe vapors. Do not use near open flame or
excessive heat. The flash point is 100-138° F (38-59° C). If you become dizzy while
using cleaning solvent, get fresh air immediately and get medical aid. If solvent
contacts eyes, wash eyes with water and get medical aid immediately.
(1)
Clean all parts in dry cleaning solvent.
WARNING
Compressed air for cleaning purposes will not exceed 30 psi (207 kPa). Use only
with effective chip guarding and personal protective equipment (goggles/shield,
gloves, etc.).
(2)
Dry all parts with compressed air.
(3)
Inspect all parts for damage. Replace all damaged parts.
17-15
|