TM 9-2320-360-20-3
Section 5
DIAGNOSTIC DATA READER INFORMATION (Contd)
C.4 ECM INPUT AND OUTPUT CONFIGURATION
The view ECM Input and Output Configuration selection is the set of DDEC Ill data parameters that describe the functions
assigned to the ECM input and output connector terminals that is currently programmed in the DDEC III calibration.
NOTES:
(1) The connector cavity designations describe the physical locations of the assigned functions.
(2) The DDR displays the assigned function parameter text as described in Table 1 (Vehicle Switch Input Options) and Table 2
(ECM Output Options) on page H-278.
(3) N/A will be displayed if a function number of (0 = NONE) has been assigned to any of the connector cavities.
Parameter [7]: G1 ----------
Definition:
Indicates the functional configuration of the switch input at connector cavity G1 (diagnostic request
switch).
Parameter [22]: Al ----------
Definition:
Indicates the functional configuration of the output at connector cavity Al (engine brake enable).
Parameter [23]: J3 ----------
Definition:
Indicates the functional configuration of the PWM output at connector cavity J3 (power train demand).
H-276
|