TM 9-2320-360-20-3
Section 5
DIAGNOSTIC DATA READER INFORMATION (Contd)
C.2 VSG CONFIGURATION
The view VSG Configuration selection is the set of DDEC Ill data parameters that identifies the Variable Speed Governor
(VSG) configuration that is currently programmed In the DDEC III calibration.
Parameter [1]: VSG DROOP RPM
Definition:
Indicates the variable speed governor droop in RPM.
Typical Range: 0 to 300 RPM
Parameter [2]: VSG MIN RPM
Definition:
Indicates the minimum variable speed governor RPM.
Typical Range: (IDLE to VSG MAX RPM) IDLE = DDEC Unique ID 218 - Byte a
Parameter [3]: VSG MAX RPM
Definition:
Indicates the maximum variable speed governor RPM.
Typical Range: (VSG MIN RPM to RATED) RPM
Parameter [4]: ALT VSG YIN
Definition:
Indicates the alternate variable speed governor minimum RPM. N/A will be displayed it
(Function #16 -- ALT VSG MIN) is not configured as a vehicle input switch.
Typical Range: (VSG MIN RPM to VSG MAX RPM) RPM, or N/A.
H-272
|