TM 9-2320-360-20-1
TRANSDUCER VOLTAGE TEST
Table 2-13
Volts
PSI
(plus/minus 0.2 volts)
75
3.5
70
3.3
60
2.9
NOTE
Tire pressures must be between 75 psi (517 kPa)
before beginning test to measure complete range of
transducer voltage output.
STE/ICE Test #50 is used to monitor pressures at
porting block
50
2.5
(1)
Remove hose no 2102 and elbow from porting block.
40
2.0
(2)
Install STE/ICE adapter and 0-1000 psi (0-6895 kPa) pressure
30
1.7
transducer on porting block
20
1.3
(3)
Set CTI controller to EMERGENCY setting (TM 9-2320-360-10)
20
1.3
NOTE
CTI wiring harness must remain installed to controller
and power manifold when performing this test
(4)
Place positive (+) probe of multimeter on white transducer wire
(5)
Place negative (-) probe of multimeter on known good ground
(6)
Start engine (TM 9-2320-360-10)
(7)
Move CTI switch to ON position (TM 9-2320-360-10)
(8)
Press CTI START button (TM 9-2320-360-10)
(9)
Record transducer voltage when porting block pressure reaches
values shown in Table 2-13
(10) Shut off engine (TM 9-2320-360-10)
(11) Remove STE/ICE pressure transducer and adapter from porting block
(12) Install elbow and air hose no 2102 on porting block
POWER MANIFOLD VOLTAGE TEST
NOTE
Tire pressures must be 75 psi
(517 kPa) before beginning test
to measure correct transducer
voltage output.
CTI
wiring
harness
must
remain installed to controller
and
power
manifold when
performing this test
(1)
Place positive (+) probe of multimeter on pin 7.
wire no 1062 (white), at controller
(2)
Place negative (-) probe of multimeter on
known good ground
(3)
Start engine (TM 9-2320-360-10)
(4)
Move CTI switch to ON position
(TM 9-2320-360-10)
(5)
Press CTI START button
(TM 9-2320-360-10) and look for 3 5-4
volts on multimeter
(6)
Shut off engine (TM 9-2320-360-10)
2-869
|