TM 9-2320-360-20-1
AIR GOVERNOR PRESSURE
TEST
(1)
Remove hose no 2114 from air
governor.
NOTE
Air should escape
from air governor
port when hose no.
2114 is removed and
air pressure is at
120-125 psi
(827-862 kPa).
(2)
Start engine (TM 9-2320-360-10)
and allow air system pressure to build
up to 120-125 psi (827-862 kPa).
(3)
Shut off engine (TM 9-2320-360-10)
when air pressure builds up to
120-125 psi (827-862 kPa).
(4)
Install hose no. 2114 on air governor.
AIR DRYER PURGE TEST
NOTE
Air dryers should
purge when air
pressure is at
120-125 psi
(827-862 kPa).
(1)
Start engine (TM 9-2320-360-10)
and allow air system pressure to build
up to 120-125 psi (827-862 kPa).
(2)
Listen for both air dryers to purge.
(3)
Shut off engine (TM 9-2320-360-10)
when air pressure builds up to
120-125 psi (827-862 kPa).
2-759
|