TM 9-2320-360-20-1
Check air compressor inlet hose no 2600
and fittings for restrictions and damage.
WARNING
Air compressor discharge
hose no. 2001 gets
extremely hot during
normal air compressor
operation. Allow sufficient
time for hose to cool before
performing inspection.
Failure to comply may
result in personnel injury.
Check air compressor discharge hose no.
2001 and fittings for restrictions, leakage,
and damage.
AIR GOVERNOR TEST
(1)
Start engine (TM 9-2320-360-10).
(2)
Watch AIR PRESS gage. Green and
red needles should move up scale as
pressure builds up.
NOTE
Air will be released
from air dryers when
air governor cuts out.
(3)
Check AIR PRESS gage when air
governor cuts out. AIR PRESS gage
should read 120-125 psi (827-862
kPa) when air governor cuts out. Air
governor fails test if it does not cut
out at 120-125 psi (827-862 kPa).
2-753
|