Page Title: SERVICE BRAKE RELAY VALVE TEST
Back | Up | Next

Click here for a printed version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-360-20-1 SERVICE BRAKE RELAY VALVE TEST (1) Start engine (TM 9-2320-360-10). (2) Build up air pressure to 125 psi (862 kPa). (3) Release parking brake (TM 9-2320-360-10). (4) Apply and release service brake (TM 9-2320-360-10). WARNING Do not remove air line from relay valve.  Air pressure may be present at air line. Failure to comply may result in injury to personnel. (5) Shut off engine (TM 9-2320-360-10) (6) Loosen air line on service port of service brake relay valve No air should be present (7) Tighten air line on service port of service brake relay valve (8) Apply parking brake (TM 9-2320-360-10). Change 2  2-731