TM 9-2320-360-20-1
Table 2-1. Preventive Maintenance Checks and Services (Cont)
ITEM TO BE
NOT FULLY
ITEM
INTERVAL
CHECKED OR
PROCEDURE
MISSION
NO.
SERVICED
CAPABLE IF:
18
Semi-
WINCH AND
strands, and wear. If damaged or
broken wires
(cont)
annually
WINCH
worn, replace cable (para 17-5/17-13).
per inch on
HYDRAULICS
same strand
(CONT)
or more than
six broken
wires on all
strands in a 1
in. running
length of
cable. Maxi-
mum number
of broken
wires shall not
occur in any
two consecutive
inches of
cable; that is,
if six wires are
broken in 1 in.
of cable, none
would be al
lowed in the
next consecutive
inch.
k. Inspect hydraulic pump (2) for leaks or
k. Any leak is
obvious damage (para 2-11).
found.
I. Check winch PTO shaft (3) for cracks,
I.
PTO is
wear, or looseness. If fault is found,
cracked or
repair PTO shaft (para 17-15).
inoperative.
2-45
|