TM 9-2320-360-20-1
Table 2-1. Preventive Maintenance Checks and Services (Cont)
ITEM TO BE
NOT FULLY
ITEM
INTERVAL
CHECKED OR
PROCEDURE
MISSION
NO.
SERVICED
CAPABLE IF:
13
Semi-
TRANSFER
a. Check transfer case (1) for cracks and
a. Mounting
annually
CASE
loose or missing mounting hardware.
hardware is
missing.
b. Check transfer case input and output
b. Any class III
shaft seals (2) for leaks (para 2-11).
leaks are
found.
c. Check transfer case shift cable (3) for
c. Cable is
kinks, frays, or broken linkage. If
broken,
faults are found, replace shift linkage
kinked, or
(para 9-2).
frayed, or
linkage is
broken.
d. Perform all semiannual lubrication as
identified in LO 9-2320-360-12.
2-35
|