TM 9-2320-360-20-1 CONTINUITY TEST CAUTION Electrical power must be disconnected from circuit before continuity can be checked.  Failure to comply may result in damage to test equipment or electrical system. (1) Disconnect Intervehicular wire harness from 12 pin electrical connector. (2) Set multimeter to ohms position. (3) Connect one multimeter leads to pin D on 12 pin electrical connector. NOTE A reading of infinity indicates an open circuit (4) Connect other multimeter lead to known good ground and check reading on multimeter. INTERVEHICULAR CABLE TEST (1) Set multimeter to ohms position. (2) Connect one multimeter leads to pin A at intervehicular cable. NOTE A reading of infinity indicates an open circuit (3) Connect other multimeter lead to socket A at other end of intervehicular cable. (4) Repeat steps (2) and (3) for remaining pins and sockets B thru N. Change 1  2-628.1