TM 9-2320-360-20-1
CONTINUITY TEST
CAUTION
Electrical power must be
disconnected from circuit
before continuity can be
checked. Failure to comply
may result in damage to test
equipment or electrical
system.
(1)
Disconnect Intervehicular wire harness from
12 pin electrical connector.
(2)
Set multimeter to ohms position.
(3)
Connect one multimeter leads to pin D on 12
pin electrical connector.
NOTE
A reading of infinity indicates
an open circuit
(4)
Connect other multimeter lead to known
good ground and check reading on
multimeter.
INTERVEHICULAR CABLE TEST
(1)
Set multimeter to ohms position.
(2)
Connect one multimeter leads to pin A at
intervehicular cable.
NOTE
A reading of infinity indicates
an open circuit
(3)
Connect other multimeter lead to socket A at
other end of intervehicular cable.
(4)
Repeat steps (2) and (3) for remaining pins
and sockets B thru N.
Change 1 2-628.1
|